KINETIX® · Formulated & manufactured by ATL

R240 High-Performance Laminating Epoxy System

KINETIX® R240 is a solvent-free, low-viscosity epoxy laminating system developed for the manufacture of high-performance fibre-reinforced composite structures. Formulated for use with carbon fibre, aramid and fibreglass reinforcements, the system provides excellent fibre wet-out and mechanical properties for structural laminating applications.

100:25Mix ratio by weight
400–880 mPa·sMixed viscosity at 25°C
20–75 minPot life · 100 g at 25°C
Four hardenersH126 · H160 · H161 · H162
KINETIX R240 high performance laminating epoxy resin, 18 kg Part A resin pack

Key characteristics

Low mixed viscosity for fibre impregnation

Mixed viscosity of 400–880 mPa·s at 25°C, depending on hardener selection, supporting fibre wet-out and resin distribution during wet lay-up.

Four hardener options

H126, H160, H161 and H162 provide pot lives of 20–75 minutes (100 g at 25°C) and thin-laminate open times of approximately 2–5.5 hours.

Consistent 100:25 mix ratio by weight

A common resin-to-hardener ratio across all four hardeners simplifies mixing and allows processing times to be adjusted through hardener selection.

Solvent-free formulation

Solvent-free epoxy system developed for the manufacture of fibre-reinforced composite laminates.

Compatible with structural reinforcements

Formulated for laminating carbon fibre, aramid and fibreglass reinforcements in structural composite applications.

Ambient cure with enhanced thermal performance

Cures at ambient temperature, with elevated-temperature cure schedules available to increase HDT. Ultimate HDT ranges from 82–95°C, depending on hardener selection. View HDT by hardener →

01 · Hardener selection

One resin. Four hardeners.

Every hardener mixes at the same 100:25 by weight. Compare working and demould times, then select a hardener for its full cure data.

HardenerPot life · 100 g @ 25°CThin-laminate open timeDemould @ 25°C
H126 Super Fast20 min2 h5 h
H160 Medium35 min4 h 20 min12 h
H161* Slow50 min4 h 40 min12 h
H162 Super Slow75 min5 h 30 min14 h
R240 / H160 · Medium Mid-range pot life with a 12-hour demould at 25°C.
Pot life · 100 g @ 25°C35 min
Thin-laminate open time4 h 20
Demould @ 25°C12 h
Mixed viscosity @ 25°C600 mPa·s
Shore D · 1 day / 2 weeks80 / 82
HDT by cure schedule

42°C to an ultimate 82°C

For R240/H160, typical heat deflection temperature (HDT) increases from 42°C after 24 hours of ambient curing at 25°C to 79°C following a subsequent 8-hour post-cure at 80°C. An elevated-temperature post-cure improves thermal performance, with an ultimate HDT of 82°C achievable under the specified cure conditions.

Contact ATL Composites for cure schedule advice for your part.

Room-temperature cure Elevated-temperature cure Ultimate HDT
02 · Technical data

All four hardeners, side by side.

Components

ComponentSpeedAppearanceViscosity mPa·s @ 25°CSpecific gravity @ 25°C
R240 resin—Clear liquid16001.15
H126Super FastClear, pale brown1600.99
H160MediumClear, pale yellow300.95
H161SlowClear, pale yellow250.94
H162Super SlowClear, pale yellow200.93

Cure characteristics · mixed 100:25 by weight

Property @ 25°CH126H160H161H162
Pot life, 100 g mass in air20 min35 min50 min75 min
Thin-laminate open time2 h4 h 204 h 405 h 30
Demould time5 h12 h12 h14 h
Mixed viscosity, mPa·s880600470400
Shore D hardness, 1 day79807476
Shore D hardness, 2 weeks82827677

Heat deflection temperature (HDT) by cure schedule

Cure scheduleH126H160H161H162
1 day @ 25°C49°C42°C40°C39°C
2 weeks @ 25°C56°C49°C49°C47°C
16 h @ 40°C65°C57°C55°C58°C
16 h @ 50°C75°C67°C65°C66°C
8 h @ 60°C79°C73°C73°C71°C
8 h @ 80°C89°C79°C78°C82°C
Ultimate HDT95°C82°C82°C87°C

Typical properties provided as general guidance only — not guaranteed performance, specification limits or design data. Users are responsible for determining suitability and should conduct their own testing before use. Do not attempt to control the cure time by altering the hardener ratio. Refer to the current technical data sheet.

03 · Pack sizes & order codes

Pack sizes

Each kit combines one resin pack with one hardener pack of the same size, at 100:25 by weight.

Resin codePackHardener codePackTotal kit
RC 2404 kg
HC 126HC 160*HC 161HC 162
1 kg1 kg1 kg1 kg
5 kg
RD 24018 kg
HD 126HD 160*HD 161HD 162
4.5 kg4.5 kg4.5 kg4.5 kg
22.5 kg
RF 240192 kg
HF 126HF 160*HF 161HF 162
48 kg48 kg48 kg48 kg
240 kg

* H161 is a made-to-order product and a minimum purchase quantity is applicable.

Technician working on a vacuum-bagged composite panel
05 · Complete the laminate

Composite materials and processing consumables from one supplier.

ATL supplies reinforcement fabrics, structural core materials, vacuum bagging consumables and complementary composite products alongside KINETIX® epoxy systems. Our technical team can assist with material selection and processing compatibility.

Page 1 of the KINETIX R240 technical data sheet, showing uncured properties and cure characteristics tables PDF
06 · Technical data sheet

KINETIX® R240 Laminating

The complete technical reference for R240 with all four hardeners — the data to specify, process and check the system.

Uncured propertiesCure characteristicsHDT by cure scheduleMonitoring of cureResin quantity guidePack sizes & order codesStorageHealth & safety
PDF · 3 pages · A4 · Issued 12 October 2026
Common questions
Can I speed up or slow down the cure by changing the ratio?

No. Always mix 100:25 by weight. Change cure speed by choosing a different hardener — H126, H160, H161 or H162 — or by adjusting temperature.

How do I check a laminate is fully cured?

Cure 2–3 mm samples of the same mix in waxed lids beside the part and compare them with fully cured standards. To estimate HDT, warm a sample in water and note when it turns rubbery. Foam cores can insulate the inner skin and slow its cure.

Which hardener should I start with?

Cure time varies with the hardener selected, ambient temperature and laminate thickness. Share your part, process and conditions with our technical team and they can help you select a hardener and cure schedule.

Can ATL modify the system for my process?

KINETIX® is formulated and manufactured in-house by ATL in Australia. Where a standard system doesn’t suit your process, our chemists and engineers can discuss a tailored formulation and process support for your production application.